Display code Short designaon Default seng Seng range Address Category
P706.05 Del.overr.me 2.0 s 0.0 ... 60.0 s 0x2541:005 general
P706.06 Brk. res. behav O:disabl+error [0] Selecon list 0x2541:006 general
P707.xx Brake resistor
P707.02 Resistance value 180.0 Ω * 0.0 ... 500.0 Ω 0x2550:002 general
P707.03 Rated power 50 W * 0 ... 800000 W 0x2550:003 general
P707.04 Maximum heat 8.0 kWs * 0.0 ... 100000.0 kWs 0x2550:004 general
P707.07 Thermal load x.x % - (Read only) 0x2550:007 general
P707.08 Warning thresh. 90.0 % 50.0 ... 150.0 % 0x2550:008 general
P707.09 Error thresh. 100.0 % 50.0 ... 150.0 % 0x2550:009 general
P707.10 Warning resp. Warning [1] Selecon list 0x2550:010 general
P707.11 Error response Fault [3] Selecon list 0x2550:011 general
P708.xx Keypad setup
P708.01 CTRL&F/R keys CTRL&F/R Enable [1] Selecon list 0x2602:001 general
P708.02 Select rot.dir. Forward [0] Selecon list 0x2602:002 general
P708.03 Keypad Full Ctrl O [0] Selecon list 0x2602:003 general
P710.xx Load loss detect
P710.01 Threshold 0.0 % 0.0 ... 200.0 % 0x4006:001 general
P710.02 Delay me 0.0 s 0.0 ... 300.0 s 0x4006:002 general
P710.03 Error response No response [0] Selecon list 0x4006:003 general
P711.xx Posion counter
P711.01 Signal source Disbled [0] Selecon list 0x2C49:001 general
P711.02 Reset mode Rising edge [0] Selecon list 0x2C49:002 general
P711.03 Actual posion - - (Read only) 0x2C49:003 general
P712.xx Brake control
P712.01 Brake mode O [2] Selecon list 0x2820:001 general
P712.02 Closing me 100 ms 0 ... 10000 ms 0x2820:002 general
P712.03 Opening me 100 ms 0 ... 10000 ms 0x2820:003 general
P712.07 Closing thresh. 0.2 Hz 0.0 ... 599.0 Hz 0x2820:007 general
P712.08 Holding load 0.0 % -500.0 ... 500.0 % 0x2820:008 general
P712.12 ClosingThr delay 0 ms 0 ... 10000 ms 0x2820:012 general
P712.13 HoldLoad rampm 0 ms 0 ... 100 ms 0x2820:013 general
P712.15 Brake status - - (Read only) 0x2820:015 general
P718.xx Flying restart
P718.01 Current 30 % 0 ... 100 % 0x2BA1:001 MCTRL
P718.02 Start frequency 20.0 Hz -599.0 ... 599.0 Hz 0x2BA1:002 MCTRL
P718.03 Restart me 5911 ms * 1 ... 60000 ms 0x2BA1:003 MCTRL
P718.08 Fl.res.frequency x.x Hz - (Read only) 0x2BA1:008 MCTRL
P721.xx Mains fail. ctrl
P721.01 Enable funcon Disabled [0] Selecon list 0x2D66:001 general
P721.02 DC-bus act.level 0 % * 60 ... 90 % 0x2D66:002 general
P721.03 Gain V-ctrl 0.01000 Hz/V 0.00001 ... 0.50000 Hz/V 0x2D66:003 general
P721.04 Res. me V-ctrl 20 ms 5 ... 2000 ms 0x2D66:004 general
P721.05 DC voltage setp. 100 % 80 ... 110 % 0x2D66:005 general
P721.06 Setp. ramp 20 ms 1 ... 16000 ms 0x2D66:006 general
P721.07 Clear me 20 ms 1 ... 60000 ms 0x2D66:007 general
P721.08 Restart level 0.0 Hz 0.0 ... 599.0 Hz 0x2D66:008 general
P721.09 RERT:Status - - (Read only) 0x2D66:009 general
P730.00 PIN1 protecon 0 -1 ... 9999 0x203D general
P731.00 PIN2 protecon 0 -1 ... 9999 0x203E general
P732.00 Auto-Save EPM Inhibit [0] Selecon list 0x2829 general
P740.xx Favorites se.
P740.01 Parameter 1 0x2DDD0000 0x00000000 ... 0xFFFFFF00 0x261C:001 general
P740.02 Parameter 2 0x60780000 0x00000000 ... 0xFFFFFF00 0x261C:002 general
P740.03 Parameter 3 0x2D890000 0x00000000 ... 0xFFFFFF00 0x261C:003 general