Selecon Info
84 Heavy load monitoring TRUE if the actual apparent current of the motor exceeds the threshold
for longer than the delay me. FALSE if the actual apparent current of
the motor falls below the threshold value minus 5% (hysteresis) Heavy
load monitoring ^ 241 .
102 Sequence suspended (from version 03.00) Status signal of the "sequencer" funcon:
TRUE if the sequence is currently suspended.
4Sequencer ^ 91
103 Sequence done (from version 03.00) Status signal of the "sequencer" funcon:
TRUE if the sequence is completed (nal segment has been passed
through).
4Sequencer ^ 91
104 Local control acve TRUE if local keypad control ("LOC") acve. Otherwise FALSE.
105 Remote control acve TRUE if remote control ("REM") via terminals, network, etc. acve. Oth-
erwise FALSE.
106 Manual setpoint selecon acve TRUE if manual setpoint selecon ("MAN") via keypad acve. Otherwise
FALSE.
•
Selecon of the trigger for the "Acvate keypad setpoint" funcon in
0x2631:016 (P400.16).
107 Automac setpoint selecon acve TRUE if automac setpoint selecon ("AUTO") via terminals, network,
etc. acve. Otherwise FALSE.
201 Internal value (from version 05.00) Internal values of the manufacturer.
202 Internal value (from version 05.00)
203 Internal value (from version 05.00)
204 Internal value (from version 05.00)
205 Internal value (from version 05.00)
206 Internal value (from version 05.00)
Start, stop and rotang direcon commands
Flexible I/O conguraon of the start, stop and rotang direcon commands
Trigger list
66