EasyManua.ls Logo

Lenze i550 - Page 699

Lenze i550
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Designaon Default seng Category Data type Factor A M
0x402A:005
(P805.05)
Sequencer segment 5: Analog outputs 0.00 VDC Sequencer U16 100 P -
0x402A:006
(P805.06)
Sequencer segment 5: PID setpoint 0.00 PID unit Sequencer I16 100 P -
0x402A:007
(P805.07)
Sequencer segment 5: Torque setpoint 100.0 % Sequencer I16 10 P -
0x402A:008 Sequencer segment 5: NetWordOUT2 0 Sequencer U16 1 P -
0x402A:009 Sequencer segment 5: Reserved 0 Sequencer U32 1 P -
0x402B:001
(P806.01)
Sequencer segment 6: Frequency setpoint 0.0 Hz Sequencer I16 10 P -
0x402B:002
(P806.02)
Sequencer segment 6: Acceleraon/deceleraon 5.0 s Sequencer U16 10 P -
0x402B:003
(P806.03)
Sequencer segment 6: Time 0.0 s Sequencer U32 10 P -
0x402B:004
(P806.04)
Sequencer segment 6: Digital outputs 0 Sequencer U8 1 P -
0x402B:005
(P806.05)
Sequencer segment 6: Analog outputs 0.00 VDC Sequencer U16 100 P -
0x402B:006
(P806.06)
Sequencer segment 6: PID setpoint 0.00 PID unit Sequencer I16 100 P -
0x402B:007
(P806.07)
Sequencer segment 6: Torque setpoint 100.0 % Sequencer I16 10 P -
0x402B:008 Sequencer segment 6: NetWordOUT2 0 Sequencer U16 1 P -
0x402B:009 Sequencer segment 6: Reserved 0 Sequencer U32 1 P -
0x402C:001
(P807.01)
Sequencer segment 7: Frequency setpoint 0.0 Hz Sequencer I16 10 P -
0x402C:002
(P807.02)
Sequencer segment 7: Acceleraon/deceleraon 5.0 s Sequencer U16 10 P -
0x402C:003
(P807.03)
Sequencer segment 7: Time 0.0 s Sequencer U32 10 P -
0x402C:004
(P807.04)
Sequencer segment 7: Digital outputs 0 Sequencer U8 1 P -
0x402C:005
(P807.05)
Sequencer segment 7: Analog outputs 0.00 VDC Sequencer U16 100 P -
0x402C:006
(P807.06)
Sequencer segment 7: PID setpoint 0.00 PID unit Sequencer I16 100 P -
0x402C:007
(P807.07)
Sequencer segment 7: Torque setpoint 100.0 % Sequencer I16 10 P -
0x402C:008 Sequencer segment 7: NetWordOUT2 0 Sequencer U16 1 P -
0x402C:009 Sequencer segment 7: Reserved 0 Sequencer U32 1 P -
0x402D:001
(P808.01)
Sequencer segment 8: Frequency setpoint 0.0 Hz Sequencer I16 10 P -
0x402D:002
(P808.02)
Sequencer segment 8: Acceleraon/deceleraon 5.0 s Sequencer U16 10 P -
0x402D:003
(P808.03)
Sequencer segment 8: Time 0.0 s Sequencer U32 10 P -
0x402D:004
(P808.04)
Sequencer segment 8: Digital outputs 0 Sequencer U8 1 P -
0x402D:005
(P808.05)
Sequencer segment 8: Analog outputs 0.00 VDC Sequencer U16 100 P -
0x402D:006
(P808.06)
Sequencer segment 8: PID setpoint 0.00 PID unit Sequencer I16 100 P -
0x402D:007
(P808.07)
Sequencer segment 8: Torque setpoint 100.0 % Sequencer I16 10 P -
0x402D:008 Sequencer segment 8: NetWordOUT2 0 Sequencer U16 1 P -
0x402D:009 Sequencer segment 8: Reserved 0 Sequencer U32 1 P -
0x402E:001
(P822.01)
End segment: Frequency setpoint 0.0 Hz Sequencer I16 10 P -
* Default seng depending on the size.
Appendix
Parameter aribute list
699

Table of Contents

Other manuals for Lenze i550

Related product manuals