Address Name / seng range / [default seng] Info
2 Analog input 1 The setpoint is dened as analog signal via the analog input 1.
4Analog input 1^ 255
3 Analog input 2 The setpoint is dened as analog signal via the analog input 2.
4Analog input 2^ 260
4 HTL input (from version 04.00) The digital inputs DI3 and DI4 can be congured as HTL input to use an
HTL encoder as setpoint encoder or dene the setpoint as a reference
frequency ("pulse train").
4HTL encoder^ 162
4Congure digital inputs DI3/DI4 for detecng a pulse train^ 247
5 Network The setpoint is dened as process data object via the network.
4Dene setpoint via network^ 296
11 Frequency preset 1 For the setpoint selecon, preset values can be parameterised and selec-
ted.
4Setpoint presets^ 87
12 Frequency preset 2
13 Frequency preset 3
14 Frequency preset 4
15 Frequency preset 5
16 Frequency preset 6
17 Frequency preset 7
18 Frequency preset 8
19 Frequency preset 9
20 Frequency preset 10
21 Frequency preset 11
22 Frequency preset 12
23 Frequency preset 13
24 Frequency preset 14
25 Frequency preset 15
31 Segment preset 1 (from version 03.00) For the setpoint selecon, the segment presets parameterised for the
"sequencer" funcon can be selected as well.
4Sequencer ^ 91
32 Segment preset 2 (from version 03.00)
33 Segment preset 3 (from version 03.00)
34 Segment preset 4 (from version 03.00)
35 Segment preset 5 (from version 03.00)
36 Segment preset 6 (from version 03.00)
37 Segment preset 7 (from version 03.00)
38 Segment preset 8 (from version 03.00)
50 Motor potenometer The setpoint is generated by the "motor potenometer" funcon. This
funcon can be used as an alternave setpoint control which is control-
led via two signals: "MOP setpoint up" and "MOP setpoint down".
4Motor potenometer (MOP) ^ 89
201 Internal value (from version 05.00) Internal values of the manufacturer.
202 Internal value (from version 05.00)
203 Internal value (from version 05.00)
204 Internal value (from version 05.00)
205 Internal value (from version 05.00)
206 Internal value (from version 05.00)