214733 406 Revision A
Problem Solution
Section
Symptom: Starter cranks slowly or will not operate.
Low battery output Check battery charge.
Maintaining a Battery, page 342
Loose or corroded battery connections Clean and tighten loose connections.
Maintaining a Battery, page 342
Controls not in NEUTRAL
Move GSL to NEUTRAL.
Starting the Engine, page 115
Controls not in NEUTRAL
Move steering wheel to CENTER
position.
Driving in Reverse in Cab-Forward
Mode, page 127
Controls not in NEUTRAL Disengage header.
Engaging and Disengaging the Header,
page 190
Relay not functioning Check relay and wire connections.
Checking and Replacing Fuses, page
379
Main fuse defective/blown
Replace main fuse.
Checking and Replacing Fuses, page
379
Key power fuse blown
Replace.
Checking and Replacing Fuses, page
379
Key switch worn or terminals loose Contact Dealer. Contact Dealer
Switch at Interlock not closed or
defective
Adjust switch or replace Contact your
Dealer.
Contact Dealer
Crankcase oil too high viscosity Use recommended oil.
5.1.3 Lubricants, Fluids, and System
Capacities, page 249
TROUBLESHOOTING

Table of Contents