OPERATOR’S STATION
4. Press SELECT (D) until DISK OVERLOAD SPD? is
displayed on the upper line.
The current overload speed is displayed on the
lower lin e.
NOTE:
Default setting is -300 SPM. Range is -500 to
-100 rpm.
5. Press left (B) or right (C) arrows to set disc overload
speed. Press SELECT (D).
6. Press P ROGRAM (A ) to exit Prog r am ming Mode or
press SELECT (D) to proceed to next WINDROWER
SETUP action.
Figure 3.10
4: M155 Disc Overload Speed
Setting th
e Header Knife Speed
NOTE:
The header MUST be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header. For more information, refer to 4.5 Attaching and
Detaching Headers, page 213.
1. Turn ignition key to RUN , or start the eng ine.
2. Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
WINDROWER SETUP? is displayed on the
upper line.
NO/YES is displayed on the lower line .
3. Press right (B) arrow to select YES. Press SELECT (C).
SET KNIFE SPEED? is displayed.
The current knife speed is displayed on the
lower lin e.
Figur
e 3.105: M155 CDM Programming Buttons
147649 105 Revision A