MAINTENANCE AND S ERVICING
10. Reinstall control panel (B) with ve screws (A).
Figure 5 .34: Header Control Panel
5.5.6 H eating, Ventilating, and Air Conditioning (HVAC) System
Fresh Air Intake Fil ter
The fresh air lter is located outside the right rear of the cab and should be serviced every 50 hours under normal
conditions and m ore frequently in severe conditions.
Removing Fresh Air Filter
DANGER
To avoid bodily injury or death from unexpected startup of the machine, always stop the engine and remove
the key from the ignition before leaving the operator ’s seat for any reason.
1. Open the r
ight cab-forward platform. Refer to 5.3.1
Opening P
latforms (Standard Position), page 309.
2. Rotate latch (A) and slide lter tray (B) out of
the housing.
Figure 5.35:
Filter Tra y