01 Ttracking application error
Tracking information was lost. The machine failed to give notice of the tracking
information to the tracking SDK application.
Cycle the machine off/on
02 Management server error
The machine failed to give notice of the tracking information to the
management server. Tracking information was lost, and the machine could not
count correctly.
Cycle the machine off/on
SC641-00 D Engine serial communication error CTL
An error occurs in serial communication with engine.
SC641-1: Timeout error
SC641-2: Retry over
SC641-3: Download error
SC641-4: UART error
Cycle the machine off/on
SC650 C @Remote communication error (Cumin-M) CTL
01 The authentication for the Cumin-M fails failed at a dial up connection due to one
or more of the following:
Incorrect SP settings
Disconnected telephone line
Disconnected modem board
Disconnected wireless LAN card
Check and set the correct user name (SP5-816-156) and password
(SP5-816-157).