SC666-01 D 37 V Overcurrent Error (Power ON/Recover from Sleep)
Power of 37 V is shut down by detecting overcurrent upon setting the main
power switch to ON or in recovery from Sleep mode.
Print head defective, HRB defective, BiCU defective, harness short-
circuited, air release SOL defective
Replace the print head, HRB, BiCU, harness, or air release SOL.
SC666-02 D 37 V Overcurrent Error (Operation)
Power of 37 V is shut down by detecting overcurrent during operation.
Print head defective, HRB defective, BiCU defective, harness short-
circuited, air release SOL defective
Replace the print head, HRB, BiCU, harness, or air release SOL.
SC669 D EEPROM Communication Error
Five attempts to communicate between the EEPROM and NVRAM failed.
Device ID data corrupted
Connection between controller board and MCU loose, broken,
defective
NVRAM defective
Controller board defective
MCU defective
SC669-02 D EEPROM1 channel error