SC666-01 D 37 V Overcurrent Error (Power ON/Recover from Sleep)
Power of 37 V is shut down by detecting overcurrent upon setting the main
power switch to ON or in recovery from Sleep mode.
• Print head defective, HRB defective, BiCU defective, harness short-
circuited, air release SOL defective
• Replace the print head, HRB, BiCU, harness, or air release SOL.
SC666-02 D 37 V Overcurrent Error (Operation)
Power of 37 V is shut down by detecting overcurrent during operation.
• Print head defective, HRB defective, BiCU defective, harness short-
circuited, air release SOL defective
• Replace the print head, HRB, BiCU, harness, or air release SOL.
SC669 D EEPROM Communication Error
Five attempts to communicate between the EEPROM and NVRAM failed.
• Device ID data corrupted
• Connection between controller board and MCU loose, broken,
defective
• NVRAM defective
• Controller board defective
• MCU defective
SC669-02 D EEPROM1 channel error
6. Troubleshooting
696
RTB 44

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh MP CW2201 and is the answer not in the manual?

Ricoh MP CW2201 Specifications

General IconGeneral
Color PrintingYes
Scan Resolution600 dpi
Standard InterfacesEthernet, USB
Paper SizeA4
Operating SystemsWindows
Power SourceAC 100-240V, 50/60Hz

Related product manuals