SC680-02 D DSP Initialization Error
A WDT error or communication error is generated because of DSP runaway
after compleetion of DSP start.
Communication is not established after a specified period of time after DSP
start is completed.
• KISSIN defective, BiCU defective
• Cycle the machine off/on
• If not repaired, replace BICU.
SC680-03 D DSP Operation Error
A WDT error or communication error is generated because of DSP runaway
on DSP operation.
• KISSIN defective, BiCU defective
• Cycle the machine off/on
• If not recovered, replace the BICU.
SC681-01 D KISSIN Initialize Error
KISSIN ID check fail
• KISSIN defective, BiCU defective
• Cycle the machine off/on
• If not recovered, replace the BICU.
SC685 C Ink Collector Tank Communication Error
The error report is received from the device in communication with the ink
collector tank (ID Chip) and retried 3 times, but communication is not
retrieved.
SC685-02 C Channel Error (Path Disconnected)
• Replace the BiCU
6. Troubleshooting
700