pcodes.fm
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
A-9
System Programming Codes (Expert Mode Codes)
16 18 2 Internal calls; select station/group:
● up to and including V1.2 = 70
● V3.0 or later =
– 1 – 500 for HiPath 3750, HiPath 3700
– 1 – 376 for HiPath 3550, HiPath 3500
– 1 – 70 for all other systems
16 18 3 External calls, day; select station/group:
● up to and including V1.2 = 1 – 70
● V3.0 or later =
– 1 – 500 for HiPath 3750, HiPath 3700
– 1 – 376 for HiPath 3550, HiPath 3500
– 1 – 70 for all other systems
16 18 4 External calls, night; select station/group:
● up to and including V1.2 = 1 – 70
● V3.0 or later =
– 1 – 500 for HiPath 3750, HiPath 3700
– 1 – 376 for HiPath 3550, HiPath 3500
– 1 – 70 for all other systems
16 18 5 Number of rings (1 to 15) for station/group
16 18 6 Night bell, location for station/group
16 18 7 Night bell, mode:
1 = Immediate connect, 2 = After timeout
16 18 8 Call forwarding (CF) on busy, 0 = Do not forward call, 1 = Forward call
16 19 Ring cadence: 0 = Ring type 1, 1 = Ring type 2, 2 = Ring type 3
16 20 DTMF DID: 0 = denied, 1 = allowed
16 21 Ringback protection (Brazil): 0 = off, 1 = on
17 Networking
17 11 Simplified dialing: 0 = Off, 1 = On
17 12 Assign trunk group; select slot/trunk and assign trunk group
Route 1-8 (HiPath 3350, HiPath 3300)
Route 1-16 (HiPath 3750, HiPath 3550, HiPath 3700, HiPath 3500)
17 13 Overflow route; select route and assign overflow route
17 14 Trunk type CO/CS; select trunk type: 0 = CO, 1 = CS
17 15 Route name; select route and enter name (optiset E memory and opti-
Point 600 office only)
17 16 Route seizure; Route selection: 0=cyclic, 1= linear
Table A-3 Expert Mode Codes
Code Function