System Programming Codes (Expert Mode Codes)
P31003-H3550-S403-4-7620, 02/05
A-12 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
pcodes.fm
20 3 Reference clock
20 3 1 Allowed nos. list; select position (slot and port)
20 3 2 Denied nos. list; select position (slot and port)
20 4 EU parameters (not for U.S.)
20 4 1 S
0
port configuration; select slot/port and determine connection type (not
for U.S.):
1 = Automatic
2 = Euro CO PP
3 = Euro CO PMP
4 = Euro bus
5 = CorNet 1
6 = CorNet 2
7 = ECMA-QSIG
8 = ISO-QSIG
20 4 2 S2M port configuration; select slot/port and determine connection type
(not for U.S.):
1 = Euro CO PP
2 = CorNet 1
3 = CorNet 2
4 = ECMA-QSIG
5 = ISO-QSIG
20 4 3 S
0
bus MSN (for verification purposes only)
20 4 4 Call forwarding PMP
20 4 4 1 Multiple subscriber numbers, select index, 1 to 10
20 4 4 2 MSN trunks, select index, 1 to 10
20 5 US parameters (for U.S. only)
20 5 1 BRI parameter
20 5 1 1 CO/protocol:
1 = AT&T/NI 1
2 = AT&T/Custom
3 = Siemens/NI 1
4 = NT/NI 1
20 5 1 2 SPID admin, select station, select slot/port
20 5 1 3 CAID admin, stn., select CAID
20 5 1 4 PDID admin, stn., select PDID
Table A-3 Expert Mode Codes
Code Function