Page #135 background imageLoading...
Page #135 background image
boards.fm
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
3-69
Boards for HiPath 3000
Central Boards
Technical specifications
Nominal voltage range: 100 VAC - 240 VAC
Nominal frequency: 50 Hz - 60 Hz
Ring generator: 75 VAC, 20/25/50 Hz
Partial voltages: +5 Vdc, –48 V
Battery charger: 4 x 12 V (40.8 V-55.2 V)
Power consumption: 180 W
Bridging times
Table 3-28 lists the maximum possible bridging times (emergency battery operation in case
of power failure) with battery pack S30122-K5928-X (48 V/1.2 Ah), depending on the sys-
tem.
Table 3-28 UPSC-D - Bridging Times with Battery Pack S30122-K5928-X (48 V/
1.2 Ah)
System Power sup-
ply unit
Load levels Maximum bridg-
ing time
HiPath 3350 UPSC-D Normal output load = 5 V: 3 A;
–48 V: 0.5 A; ringing approx. 2 VA
19 min
HiPath 3550 UPSC-D Normal output load 100 % = 5 V: 8 A;
–48 V: 1.1 A; ringing approx. 4 VA
6 min
HiPath 3550 UPSC-D Normal output load 60 % = 5 V: 4.8 A;
–48 V: 0.66 A; ringing approx. 2 VA
15 min
HiPath 3550 UPSC-D with
EPSU2
Normal output load 100 % = 5 V: 8 A;
–48 V: 2.5 A (external via EPSU2);
ringing approx. 4 VA
17 min
Measurement conditions:
All measurements were performed at a room temperature of approximately 23 °C
(73.4°F).
The batteries were fully charged when the measurement was started.

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals