Boards for HiPath 3000
P31003-H3550-S403-4-7620, 02/05
3-220 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
boards.fm
Peripheral Boards
Connecting ISDN terminals to HiPath 3750, HiPath 3700 (for U.S. only)
S
0
bus with MW jack
You must change the signal sequence to connect up ISDN telephones. Transmit wires must be
on the inside; receive wires on the outside (see Figure 3-92).
To do so, jumper the four wires on the provided line cord to the pins for the STMD8 ports on the
main distribution frame (MDF).
The ISDN terminals must have their own local power supply.
S
0
bus wiring from STMD8 port on MDF or from optiset E ISDN adapter (for U.S. only)
Figure 3-92 STMD8 - S
0
Bus Wiring from STMD8 Port or from ISDN Adapter (for U.S. only)
MW8 jack 2
(8-pin)
MW8 jack 1
(8-pin)
STMD8 port on
MDF (port 1 shown)
MW8 jack 1
(8-pin)
MW8 = Cross the wires as shown
(not required in S
0
bus from ISDN
adapter).
0
ABCDEF
MNOGHI
PQRSTUV
↵←
↑↵
123
456
789
0
ABCDEF
MNOJKLGHI
PQRSTUVWXYZ
optiset E ISDN
adapter
MW8 jacks 2
to 7 (8-pin)
26
1
27
2
Contact is always estab-
lished using the center
pins
Last MW8 jack
(8-pin)
SR
SX
SX
SR
1
2
3
4
5
6
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
SX
SX
SR
SR
.
.
.
100 /0.25 W
Terminating
resistors in the last
jack

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals