Guided Maintenance
3 Error in CRC checksum Check transferred APS
version and re-transfer
APS.
If error is still present, re-
place MMC module.
4 Return to old APS, default CDB loaded
5 Return to old APS, old CDB loaded
6 APS Transfer disconnect Transfer APS again
7 Country data successfully transferred
8 Error occurred when deleting old APS on
MMC
Transfer APS again.
If error is still present, re-
place MMC module.
9 Block length error during APS transfer Transfer APS again
10 Remaining length error during APS trans-
fer
Transfer APS again
Error Class B-16 - General Errors
1 Error in pool administration (rel_pool_ele) Hard restart Notify appropriate service
support
2 Error in pool administration
(get_trans_store)
Hard restart
3 Error in pool administration
(get_trans_store)
Hard restart
4 Error during COSMOS send call Hard restart
5 Error during COSMOS timer call Hard restart
6 Error during COSMOS receive call Hard restart
7 COSMOS records error (recovery) Hard restart
8 Error while handling real-time clock
9 Watchdog error Hard restart
10 Manual hard restart
11 Manual reload
12 System had no voltage Notify appropriate service
support
13 Automatic customer data backup (CDB
backup) not performed
14 Unidentified hard restart
Table 12-7 HiPath 3000 Class B Error Messages