Service
P31003-H3550-S403-4-7620, 02/05
12-52 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
service.fm
Guided Maintenance
3 Error in CRC checksum – Check transferred APS
version and re-transfer
APS.
If error is still present, re-
place MMC module.
4 Return to old APS, default CDB loaded –
5 Return to old APS, old CDB loaded –
6 APS Transfer disconnect – Transfer APS again
7 Country data successfully transferred – –
8 Error occurred when deleting old APS on
MMC
– Transfer APS again.
If error is still present, re-
place MMC module.
9 Block length error during APS transfer – Transfer APS again
10 Remaining length error during APS trans-
fer
– Transfer APS again
Error Class B-16 - General Errors
1 Error in pool administration (rel_pool_ele) Hard restart Notify appropriate service
support
2 Error in pool administration
(get_trans_store)
Hard restart
3 Error in pool administration
(get_trans_store)
Hard restart
4 Error during COSMOS send call Hard restart
5 Error during COSMOS timer call Hard restart
6 Error during COSMOS receive call Hard restart
7 COSMOS records error (recovery) Hard restart
8 Error while handling real-time clock –
9 Watchdog error Hard restart
10 Manual hard restart – –
11 Manual reload – –
12 System had no voltage – Notify appropriate service
support
13 Automatic customer data backup (CDB
backup) not performed
–
14 Unidentified hard restart – –
Table 12-7 HiPath 3000 Class B Error Messages
No. Meaning Action
Recovery
Action
Technician