service.fm
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
12-51
Service
Guided Maintenance
66 Out of buffers U
P0/E
/CMI: Error corrected – –
Error Class B-11 - General Errors
58 Too many layer 1 errors – Check line, possibly re-
place board
Error Class B-12 - Processor Exception
0 Reset initial stack pointer Hard restart Notify appropriate service
support
1 Reset initial program counter Hard restart
2 Interrupt access error Hard restart
3 Interrupt address error Hard restart
4 Interrupt, command not permitted Hard restart
5 Interrupt, division by zero Hard restart
6 Invalid opcode exception Hard restart
7 TRAP C or TRAP V instruction Hard restart
8 Security violation Hard restart
9 Trace Hard restart
10 Line 1010 emulator Hard restart
11 Line 1111 emulator Hard restart
12 HW breakpoint (CBFC: possible EXTEB
error)
Hard restart
13 Co-processor, security violation Hard restart
14 Formatting error, unwanted interruption Hard restart
15 Formatting error, unwanted interruption Hard restart
Error Class B-15 - APS Transfer
0 APS transfer successful APS transfer –
1 APS transfer successful, CDB OK – –
2 APS transfer successful, default CDB
loaded
––
Table 12-7 HiPath 3000 Class B Error Messages
No. Meaning Action
Recovery
Action
Technician

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals