Page #979 background imageLoading...
Page #979 background image
service.fm
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
12-61
Service
Guided Maintenance
1031 Ping not
possible
HiPath 3000/
5000 HIP no
longer available
Save event
file for error
analysis
Check HiPath 3000/
5000. Check
HG 1500. Check
LAN. Initiate HiPath
3000/5000 ping, if
necessary
adm/
fct/
vsrv/
sync
HiPath
AllServ
e
1032 X CDB trans-
fer to (<IP-
Adr>) failed
(write)
Writing data to
HiPath 3000/
5000 with speci-
fied IP address
failed
Save event
file for error
analysis
Check HiPath 3000/
5000. Check
HG 1500. Check
LAN. Initiate HiPath
3000/5000 ping, if
necessary.
Load HiPath 3000
Manager E data to
the server again.
This initiates data
transfer from the
server to HiPath
3000/5000.
vsrv HiPath
AllServ
e
1033 Data sync
tile
Modification to
database in Hi-
Path 3000/5000
reported to the
server; HiPath
3000/5000 data
loaded and
saved on the
server
adm HiPath
AllServ
e
1034 Disconnec-
tion of ob-
ject recov-
ered (%1)
sync
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
Event De-
fault
trap
Error text Meaning User reaction Cate-
gory
Source

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals