Page #980 background image
Service
P31003-H3550-S403-4-7620, 02/05
12-62 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
service.fm
Guided Maintenance
1036 X CDB trans-
fer from
(<IP-Adr>)
failed
(read)
Data reading
from HiPath
3000/5000 (with
specified IP ad-
dress in the
server) failed
Save event
file for error
analysis
Check HiPath 3000/
5000. Check
HG 1500. Check
LAN. Initiate HiPath
3000/5000 ping, if
necessary.
Activate HiPath
3000/5000 data
loading via HiPath
3000 Manager E.
vsrv HiPath
AllServ
e
1037 Interface
error (_hr=
0xzzzzzzzz
z)
If 0xzzzzzzz =
0x80070057,
this is just inter-
nal information
for Develop-
ment, otherwise
error
Save event
file for error
analysis
If an error message
appears, RgTrace-
File.txt and Carlog
File must be saved.
reg HiPath
AllServ
e
1038 User inter-
face active
on <IP-
Adr>
The user inter-
face is active
during a sync.
Trials are not
cancelled and
are cyclically re-
peated until
successful.
Information sync HiPath
AllServ
e
1039 User:
“<user-
name>” on
PC:
“<pc_name
>”: read
CDB data
from server
HiPath 3000
Manager E in-
formation about
user actions,
user reads data
from the server.
Information vsr-
vad-
min
HiPath
AllServ
e
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
Event De-
fault
trap
Error text Meaning User reaction Cate-
gory
Source

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals