8 Implements Application control
Width
1.
At the Width section for Rate Control setup, the width is equal to the implement width and
cannot be changed.
2. Tap Next to continue to Adjustments, 204.
Adjustments
At the Adjustments section for Rate Control setup, review and change settings as necessary. When
you are finished with all the settings, tap Next.
WARNING – When the implement is down and the master switch is in the On position, the machine is fully
operational. Take all necessary precautions to ensure user safety. Failure to do so could result in injury or death.
Tap... To...
Minimum Override
Speed
Change this setting. When the vehicle drops below this speed, the
system maintains the application rate for this speed. This ensures
consistent material flow at low speeds.
System Minimum
Flow
Enter the minimum flow rate required by the drive, control valve or flow
meter. This setting keeps the flow above the minimum operating level
required by the equipment.
Manual Rate Switch
Aggressiveness
Increase or decrease aggressiveness of the manual rate switch.
When the Rate switch is in the Manual position, this controls how
quickly the valve opens/closes when you use the rate
increment/decrement switch on the master switch box.
Note – This setting does not affect automatic rate control.
No/Low Flow Timeout Enter a value between 1 and 10 seconds. If the rate of application is not at
least 25% of the target rate for this length of time, the display shows a
critical fault message and the system shuts down.
Pump Disarm Switch
Turn setting on or off. If the implement has a pump disarming relay that
is connected to the controller, this setting adds a button to the Run
screen to arm and disarm the pump.
l Enable: Select this option if you have a pump disarming switch
installed.
l Disable: Select this option if you do not have a pump disarming
switch installed.
204 TMX-2050 Display User Guide Version 1.075, Revision C