EasyManua.ls Logo

Trimble TMX-2050 - Field-IQ and GNSS System Diagnostics

Default Icon
336 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field-IQ diagnostics 11 Diagnostics / troubleshooting
Field-IQ diagnostics
Operations
Item Explanation
Master Switch
On or off
Control Mode On or off
Arm Pump Tap to enable Field-IQ to control the pump.
Speed Speed you are currently traveling, or speed you have set for speed simulator
Speed Simulator Enter a value to simulate traveling speed
Current Flow Current flow rate of the channel
Actual Rate Actual rate of flow
Virtual Tank Tap to access the virtual tank tool
Target Rate Indicates the target rate 1, target rate 2, and the manually set rate
Sensors Name and pressure of sensor
Aggressiveness Aggressiveness of the control valve
Adjustments
Item Explanation
Jump Start Speed
Adjust the jump start speed. When the Field-IQsystem's Master switch is in
the jump start position, the system applies material at the rate for this speed
instead of the vehicle's current speed.
This manual override option can be used to operate the system when the
vehicle is stationary, or when GPS is unavailable.
Jump Start
Timeout
Adjust start timeout. This setting limits the length of time you can run the
jump start.
Note Auto-control resumes if Jump Start Speed is exceeded by ground
Speed.
Shut Off Speed Adjust shut off speed. The system shuts down if the implement drops below
this speed.
Version 1.075, Revision C TMX-2050 Display User Guide 311