EZ-Steer system diagnostics 11 Diagnostics / troubleshooting
System faults
Fault code: Possible cause Solution
01:Excessive manual
override
Large number of manual
overrides on one swath.
Decrease the Override Sensitivity value
02: Hardware fault General hardware fault Check all equipment and cables for
damage.
03: Controller reset
Momentary loss of power,
such as a power brownout.
Controller reset
unexpectedly.
Ensure no power cables are damaged and
that the connectors are tight. Connect the
power directly to the battery.
Download the error log and send it to your
local reseller.
04:Communication
error
Controller failed to receive
CAN messages from the EZ-
Guide Plus lightbar.
Ensure the cable connection is secure and
not damaged.
05: Bridge fault
Manual override sensitivity
is too low.
Controller is faulty.
Increase the override sensitivity value.
Obtain a repair or replacement from your
local EZ-Steer system reseller.
07: Broken motor cable Motor cable is broken. Obtain a replacement cable from your local
EZ-Steer system reseller.
08: EEPROMfault Memory error in the
controller.
Contact your local reseller and request they
download the error log.
09:No motor
connected
The motor or motor cable is
not connected to the
controller.
Ensure the motor cable is connected to
the EZ-Steer system motor and the system
controller.
Ensure all cable connections are secure
and not damaged.
10:Unknown fault Unknown fault in the
system.
Contact your local reseller and request they
download the error log.
11:System fault Lightbar failed to receive
messages from the
controller.
Ensure none of the cables are damaged.
Ensure all connectors are tight.