Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual2-42
116-361
PCI Error
Power Off/On
Error 116-361
Power Off/On
<PCI Bus #0 Error Detected>
Cause:
PCI Bus #0 Uncorrectable Error Detected.
(Connected with Remora EX(x4 port))
FIP 1. 311
116-362
PCI Error
Power Off/On
Error 116-362
Power Off/On
<PCI Bus #0 Host Bridge Controller Error>
Cause:
PCI Bus #0 Host Bridge Controller Error. (Con-
nected with Remora EX port)
FIP 1. 312
116-363
PCI Error
Power Off/On
Error 116-363
Power Off/On
<PCI Bus #1 Host Bridge Controller Error>
Cause:
PCI Bus #1 Host Bridge Controller Error. (Con-
nected with Remora EX port.)
FIP 1. 313
116-364
Clock Error
Power Off/On
Error 116-364
Power Off/On
<Timer Fail>
Cause:
Timer error is detected.
FIP 1. 314
116-366
PCI Error
Power Off/On
Error 116-366
Power Off/On
<PCI Bus #1 Error Detected>
Cause:
PCI Bus #1 Uncorrectable Error Detected.
(Connected with RemoraEX(x1 port))
FIP 1. 315
116-368
PCI Error
Power Off/On
Error 116-368
Power Off/On
<PCI Error Messages received from Bus #0 -
Device #1>
Cause:
Remora EX PCI x1 port Error. (Device ID 0x65
(x1))
FIP 1. 316
116-369
PCI Error
Power Off/On
Error 116-369
Power Off/On
<PCI Error Messages received from Bus #0 -
Device #0>
Cause:
Remora EX PCI x4 port Error. (Device ID 0x64
(x4))
FIP 1. 317
116-390
NVRAM Error
Power Off/On
Error 116-390
Power Off/On
<ESS NVRAM1 SIZE And ID Check Fail>
Cause:
Detected by consistency check between NVRAM
size requested by the system and actual size and
consistency check of ID recorded at the first
power-on.
FIP 1. 318
Status
Code
(3610)
LCD Message Name/Description of Error FIP