Specifications
Phaser 3610, WorkCentre 3615 Service Manual 8-27
ID Print
User name can be printed. The printing position can be selected from top right, top left, bottom right,
and bottom left (Only for PCL6). The user selects using the operator panel whether user name is
printed or not and where it is printed.
Non-Genuine Mode
When the life of a Print cartridge has ended, the printer stops accepting print requests (the life of a
Print cartridge is counted by the counter in CRUM). Taking into consideration that some users use
refilled Print cartridges they get from remanufactures, the printer can accept print requests issued by
the user via the operator panel even if the life of the Print cartridge has ended. When the mode has
been changed so that the printer does not stop even after the life end of the Print cartridge, the printer
displays a message on the operator panel indicating e mode change. When the printer operates in this
mode, print image quality is not guaranteed. Remaining toner level is not displayed, either (as CRUM
data can not be guaranteed).
Cable Characteristics
With pseudo cable from 0 to 15km, the highest speed shall be guaranteed for communication with
V.17, V.29, and V.27ter. For V.34, 33600bps communication speed shall be guaranteed from 0 to 2km,
31200bps or higher communication speed from 2 to 9km, and 19200bps or higher communication
speed from 9 to 15km.
Communication Load Characteristics
• Data error characteristics for noise and cable loss during communication are as follows:
• Error rate (Error frequency/Total communication quantity) < = 1/500
Incoming Call Level
Under ideal conditions (flat line, no noise, and no other line stress), normal communication shall be
guaranteed in the range from -3 through -43dBm.
For V.17, V.29, and V.27ter, the highest speed shall be guaranteed in the range from -6 through -
43dBm. For V.34, 33600bps communication speed shall be guaranteed in the range from -9 through -
19dBm, and 16800bps or higher communication speed in the range from -19 through -43dBm.
For V.34, normal communication shall be guaranteed in the range from -9 through -43dBm.