1008 CHAPTER 60: INFORMATION CENTER
Parameter
size: Configures the size of buffer.
summary: Number of statistical logs.
sizenum: Size of buffer (number of messages which can be kept), ranging from 1
to 1024. By default, the size of the buffer is 256.
level: level.
levelnum: Information level value, ranging from 1 to 8.
emergencies, alerts, critical, debugging, errors, informational,
notifications, warnings are the names of the eight log severity levels. You can
type the values or names of the desired severity levels, which are equivalent, in
commands.
Table 141 gives the details.
Description
Use the display trapbuffer command to view the attribute of trapbuffer and the
information recorded in trapbuffer.
Example
# Show the system trapbuffer attribute and the log information in trapbuffer.
<SW8800> display trapbuffer
Trapping Buffer Configuration and contents:
enabled
allowed max buffer size : 1024
actual buffer size : 256
channel number : 3 , channel name : trapbuffer
dropped messages : 0
overwrote messages : 0
current messages : 6
#Dec 31 14:01:25 2004 3Com DEV/2/LOAD FINISHED:
Trap 1.3.6.1.4.1.2011.2.23.1.12.1.20: frameIndex is 0, slotIndex 0.4
#Dec 31 14:01:33 2004 3Com DEV/2/SLOT STATE CHANGE TO NORMAL:
Trap 1.3.6.1.4.1.2011.2.23.1.12.1.11: frameIndex is 0, slotIndex 0.2
#Dec 31 14:01:40 2004 3Com DEV/2/SLOT STATE CHANGE TO NORMAL:
Trap 1.3.6.1.4.1.2011.2.23.1.12.1.11: frameIndex is 0, slotIndex 0.
info-center channel
name
Syntax
info-center channel channel-number name channel-name
undo info-center channel channel-number
View
System view
Parameter
channel-number: Channel number, ranging from 0 to 9, that is, system has ten
channels.