890 CHAPTER 51: POE PSU SUPERVISION COMMANDS
Parameter
None
Description
Use the display poe-power alarm command to display detailed alarm 
information about the PoE PSUs.
Example
# Display detailed alarm information about the PoE PSUs.
<SW8800> display poe-power alarm 
 PSU alarm detail, PSU number : 2 
 PSU 1 alarm : NORMAL 
 PSU 2 alarm : NOTLINK      Controller/Rectifier communication  Fail
/Rectifier
 not in present 
display poe-power 
dc-output state
Syntax
display poe-power dc-output state
View
Any view
Parameter
None
Description
Use the display poe-power dc-output state command to display the current 
DC output state of the PoE PSUs.
Example
# Display the current DC output state.
<SW8800> display poe-power dc-output state 
DC Output State : Normal 
Tabl e 121   Description on the fields of the display poe-power alarm command
Field  Description 
NORMAL  Normal 
NOTLINK  The PSU is disconnected. That is, the controller was able to communicate with 
the PSU; but it cannot now. Power-cycling the unit or re-inserting a new PSU 
can resolve this problem. 
INERROR  The PSU input is in trouble. Restoring the AC input can resolve this problem. 
OUTERROR  The PSU output is in trouble, the PSU cannot output normal DC voltage. 
HIGHVOL  The PSU is over-voltage. The PSU is shut down because the output voltage is 
too high. 
HIGHTEP  It is overheated in the PSU. 
FANERROR  The PSU fan is in trouble. 
CLOSE  The PSU is shut down remotely. 
CURLIMIT  The PSU is current limited.