EasyManua.ls Logo

3Com 8807 - History-Command Max-Size

3Com 8807
1099 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Logging in to Switch Commands 51
<SW8800>
Option 2: Input in multiple lines
[SW8800] header shell % SHELL:
(After you press the <Enter> key, the system prompts the following message.)
Input banner text, and quit with the character ’%’.
Go on inputting the rest text and end your input with the first letter:
Hello! Welcome %
(Press the <Enter> key)
[SW8800]
When you log in to the switch again, the following is displayed.
[SW8800] quit
<SW8800> quit
Please press ENTER
%SHELL:
(The character "%" is contained in the header.)
Hello! Welcome
<SW8800>
history-command
max-size
Syntax
history-command max-size value
undo history-command max-size
View
User interface view
Parameter
value: Defines the size of the history buffer, ranging from 0 to 256. By default, the
size is 10, that is, 10 history commands can be saved.
Description
Use the history-command max-size command to configure the size of the
history command buffer.
Use the undo history-command max-size command to restore default size of
the history command buffer.
Example
# Set the history buffer to 20, namely saving 20 history commands.
<SW8800>system-view
System View: return to User View with Ctrl+Z.