118 CHAPTER 8: IP PERFORMANCE CONFIGURATION COMMANDS
tcp timer syn-timeout Syntax
tcp timer syn-timeout time-value
undo tcp timer syn-timeout
View
System view
Parameter
time-value: TCP synwait timer value measured in seconds, whose value ranges
from 2 to 600. The default time-value is 75 seconds.
Description
Use the tcp timer syn-timeout command to configure the TCP synwait timer.
Use the undo tcp timer syn-timeout command to restore the default value of
the timer.
TCP enables the synwait timer if a SYN packet is sent. The TCP connection is
terminated if the response packet is not received.
Related command: tcp timer fin-timeout, tcp window.
Example
# Configure the TCP synwait timer value as 80 seconds.
<SW8800> system-view
System View: return to User View with Ctrl+Z.
[SW8800] tcp timer syn-timeout 80
tcp window Syntax
tcp window window-size
undo tcp window
View
System view
Parameter
window-size: The size of the sending and receiving buffers measured in kilobytes
(KB), whose value ranges from 1 to 32. By default, the window-size is 8KB.
Description
Use the tcp window command to configure the size of the sending and receiving
buffers of the connection-oriented Socket.
Use the undo tcp window command to restore the default size of the buffer.
Related command: tcp timer fin-timeout, tcp timer syn-timeout.
Example
# Configure the size of the sending and receiving buffers as 3KB.

Table of Contents