892 CHAPTER 51: POE PSU SUPERVISION COMMANDS
View
Any view
Parameter
None
Description
Use the display supervision-module information command to display the
name of the supervision module, power supply model, specifications and output
power, and other information.
Example
# Display current information about the power system
<SW8800> display supervision-module information
Supervision Module Version : 2.0
Supervision Module Name :Spring Pms
Power Type :PSE4500-A
Power Rating Value : 2250 W (220V)/1125 W(110V)
Power Current Value : 53 W
Power Remaining Value : 2197 W
Power Peak Value : 0 W
Power Average Value : 0 W
PSU Number : 2
PSU 1
Rating Output Power : 2500 W
Hard Version Info :NP 2500
PSU 2
Rating Output Power : 2500 W
Hard Version Info :NP 2500
Tabl e 123 Description on the fields of the display supervision-module information
command
Field Description
Supervision Module Version Software version of the supervision module
Supervision Module Name Name of the supervision module
Power Type Power type
Power Rating Value Rated power of the power system
Power Current Value Current consumption power of the power system
Power Remaining Value Current remaining power of the power system
Power Peak Value Peak power of the power system
Power Average Value Average power of the power system
Rating Output Power Rated output power. When one or two PSUs are available, it is
2250 W for 220 VAC input and 1125 W for 110 VAC input.
When three PSUs are available, it is 4500 W for 220 VAC input
and 2250 W for 110 VAC input.