Parameter
Address Name / seng range / [default seng] Info
0x2949:001
(P337.01)
Torque limit source selecon: Posive torque limit
source
(Trq. lim. source: Pos. torqlim src)
•
From version 03.00
Selecon of the source for the posive torque limit source.
0 Max torque Posive torque limit source = Max torque 0x6072 (P326.00).
1 Fixed Limit 0.0 % Posive torque limit source = 0.0 %.
2 Analog Input 1 The posive torque limit source is dened as analog signal via the analog
input 1.
4Analog input 1 ^ 255
3 Analog Input 2 The posive torque limit source is dened as analog signal via the analog
input 2.
4Analog input 2 ^ 260
4 Posive torque limit Posive torque limit source = Posive torque limit 0x60E0.
5 Network target torque The posive torque limit source is dened as process data object via net-
work.
4Mappable parameters for exchanging setpoints and actual val-
ues ^ 299
201 Internal value (from version 05.03) Internal values of the manufacturer.
202 Internal value (from version 05.03)
203 Internal value (from version 05.03)
204 Internal value (from version 05.03)
205 Internal value (from version 05.03)
206 Internal value (from version 05.03)
0x2949:002
(P337.02)
Torque limit source selecon: Negave torque limit
source
(Trq. lim. source: Neg. torqlim src)
•
From version 03.00
Selecon of the source for the negave torque limit source.
0 (-) Max torque Negave torque limit source = (-) Max torque 0x6072 (P326.00).
1 Fixed Limit 0.0 % Negave torque limit source = 0.0 %.
2 Analog Input 1 The negave torque limit source is dened as analog signal via the ana-
log input 1.
4Analog input 1 ^ 255
3 Analog Input 2 The negave torque limit source is dened as analog signal via the ana-
log input 2.
4Analog input 2 ^ 260
4 Negave torque limit Negave torque limit source = Negave torque limit 0x60E1.
5 Network target torque The negave torque limit source is dened as process data object via
network.
4Mappable parameters for exchanging setpoints and actual val-
ues ^ 299
201 Internal value (from version 05.03) Internal values of the manufacturer.
202 Internal value (from version 05.03)
203 Internal value (from version 05.03)
204 Internal value (from version 05.03)
205 Internal value (from version 05.03)
206 Internal value (from version 05.03)
0x60E0 Posive torque limit
0.0 ... [250.0] ... 3276.7 %
•
From version 02.00
Posive torque limit source for speed control with torque limitaon.
•
100 % ≡ Rated Motor Torque. 40x6076 (P325.00)
0x60E1 Negave torque limit
0.0 ... [250.0] ... 3276.7 %
•
From version 02.00
Negave torque limit source for speed control with torque limitaon.
•
100 % ≡ Rated Motor Torque 40x6076 (P325.00)
Conguring the torque control
Basic seng
Torque limits
154