Address Name / seng range / [default seng] Info
0x2946:002
(P340.02)
Speed limitaon: Lower speed limit
(Speed limitaon: Lower limit)
-480000 ... [0] ... 480000 vel. unit
From version 03.00
Lower limit for speed limitaon.
Seng is only eecve with the selecon "Lower speed limit [5]" in
0x2946:004 (P340.04).
Entry via keypad and Lenze Tools is in rpm!
Via RPDO, the unit is vel. unit. and the scaling must be taken into
account.
± 480000 rpm = ±2 ^ 31 [n-unit]
0x2DD5 Torque setpoint
Read only: x.xx Nm
From version 03.00
Display of the current torque setpoint.
0x400A:001
(P591.01)
Process output words: NetWordOUT1
(NetWordOUTx: NetWordOUT1)
Read only
Mappable data word for the output of status messages of the inverter
via network.
Bit 0 Mapping bit 0 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:010 (P420.10)
Bit 1 Mapping bit 1 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:011 (P420.11)
Bit 2 Mapping bit 2 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:012 (P420.12)
Bit 3 Mapping bit 3 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:013 (P420.13)
Bit 4 Mapping bit 4 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:014 (P420.14)
Bit 5 Mapping bit 5 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:015 (P420.15)
Bit 6 Mapping bit 6 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:016 (P420.16)
Bit 7 Mapping bit 7 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:017 (P420.17)
Bit 8 Mapping bit 8 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:018 (P420.18)
Bit 9 Mapping bit 9 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:019 (P420.19)
Bit 10 Mapping bit 10 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:020 (P420.20)
Bit 11 Mapping bit 11 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:021 (P420.21)
Bit 12 Mapping bit 12 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:022 (P420.22)
Bit 13 Mapping bit 13 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:023 (P420.23)
Bit 14 Mapping bit 14 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:024 (P420.24)
Bit 15 Mapping bit 15 Mappable data word for the output of status messages of the inverter
via network.
Assignment of the status message: 0x2634:025 (P420.25)
Conguring the network
EtherCAT
Basic seng and opons
378