EasyManua.ls Logo

Lenze i550 - Error Codes and Remedies

Lenze i550
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Automac start aer switching on the mains voltage
The automac start can be acvated in 0x2838:002 (P203.02).
Precondions for the automac start:
The exible I/O conguraon is selected: 0x2824 (P200.00) = "Flexible I/O conguraon
[0]"
For the start command, a digital input has been congured. (In case of keypad or acvated
network control, an automac start is not possible.)
The following diagram demonstrates the funcon:
t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
t
t
t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
t
t
0x2838 002:
0x2838 002:
0x2DDD
Mains voltage
= On [1]
= Off [0]
Digital input 1 [11] Run
Constant TRUE [1]
Output signals
Output frequency
Enable inverter
Input signals
Frequency setpoint selection
FunctionTrigger
Start at power-up = "O [0]": Aer switching on the mains voltage, a renewed start command is required to start the motor.
Start at power-up = "On [1]": Aer switching on the mains voltage, the motor starts automacally if a start command is present.
Basic seng
Starng performance
44

Table of Contents

Other manuals for Lenze i550

Related product manuals