Program
Number
Program Name/Description
Input Data
Default
22-11-13
DID Translation Number Conversion
Identify for Mobile Extension
Determines when a Mobile Extension number
calls in on a DID if it will provide an Internal
Tone (1) or route the call as programmed (0).
0 = Off
1 = On
0
80-01-01
Service Tone Setup Tone 44, External Dial
Tone
It is necessary to adjust the DID/DISA dial tone
(tone 44) to a Repeat Count of 250 (by default,
this is set to 0). The system must be reset for
this change to take affect.
0 ~ 255 (0 = until On-Hook)
Refer to Table 2-
31 Service Tone
Setup Defaults,
Program
80-01-01.
80-01-01
Service Tone Setup Tone 54, Progress
Tone
By default, when calling a Mobile Extension, the
Progress Tone is played to the caller.
Refer to Table 2-
31 Service Tone
Setup Defaults,
Program
80-01-01
80-01-01
Service Tone Setup Tone 57, Off-Hook
Beep Tone - Headset Earpiece ringing Tone
If required, change the tone heard when a
Mobile Extension user goes off hook to answer
a call prior to pressing
*
. The system must be
reset for this change to take affect.
Refer to Table 2-
31 Service Tone
Setup Defaults,
Program
80-01-01
80-03-01
DTMF Tone Receiver Setup Detect Level
Select the Detect Level to be used for DTMF
Tone detection. For the extension DTMF, this
entry must allow for a detection of -25dBm. Set
the minimum detection level in Program
80-03-03. The system must be reset for this
change to take affect.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
Type 1 ~ 5 = 0