P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
A-7
System Programming Codes (Expert Mode Codes)
15 4 4 Denied 4, 10 entries
15 4 5 Denied 5, 10 entries
15 4 6 Denied 6, 10 entries
15 5 Number of authorized stations (for verification purposes only)
15 6 Lock Code
0 = No trunk access except by system speed-dialing
1 = Incoming only
2 - 7 = Allowed lists 1-6 (AL 1 to AL 6)
8 - 13 = Denied lists 1-6 (DL 1 to DL 6)
14 = Full access (full)
15 7 Toll restriction, 0 = Digit-by-digit, 1= En-bloc sending
15 8 Switched trunk authorization
15 9 Toll restriction, private
16 Incoming calls
16 10 Internal station numbers
16 10 1 Station
16 10 1 1 Boards
16 10 1 2 Change station number
16 10 1 3 Find station number
16 10 2 Groups
16 11 DID numbers; (internal) station number is displayed; enter (new) station
number
16 12 Intercept position, day; enter new destination, group or Stn. no., max. 6
digits
16 13 Intercept position, night; enter new destination, group or Stn. no., max. 6
digits
16 14 Intercept criteria
16 14 1 on RNA: 0 = no, 1 = yes
16 14 2 on Busy
16 14 2 1 Intercept 0 = no, 1 = yes
16 14 2 2 Call waiting on busy: 0 = no, 1 = yes
16 14 3 on Invalid, intercept: 0 = no, 1 = yes
Table A-3 Expert Mode Codes