EasyManuals Logo

Siemens HiPath 3000 Service Manual

Siemens HiPath 3000
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #330 background imageLoading...
Page #330 background image
Boards for HiPath 3000
P31003-H3550-S403-4-7620, 02/05
3-264 HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
boards.fm
Peripheral Boards
Jumpers S2 and S3 for GND connection
You can set the GND connection (signal ground) of the receiving (Rx) and transmitting (Tx)
lines on the CAS side here.
Recommendations for the GND connection:
symmetric line (120 ohms)
Ground the cable’s shield on the side of the connected device (NT, MUX, modem).
coaxial line (75 ohms)
Do not ground the shield on both ends of the cable.
Tx: Ground the cable’s shield on the TMCAS side.
Rx: Ground the cable’s shield on the side of the connected device (NT, MUX, modem).
GND connection Jumper setting
no signal ground (default) S2 = 1 - 2, S3 = 1 - 2
signal ground on receive lines (Rx) on the CAS side S2 = 2 - 3
signal ground on the transmit lines (Tx) on the CAS
side
S3 = 2 - 3

Table of Contents

Other manuals for Siemens HiPath 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens HiPath 3000 and is the answer not in the manual?

Siemens HiPath 3000 Specifications

General IconGeneral
BrandSiemens
ModelHiPath 3000
CategoryTelephone
LanguageEnglish

Related product manuals