Troubleshooting
Phaser 3610, WorkCentre 3615 Service Manual 2-33
050-132
Paper Jam
Open Bypass Tray,
Tray1, Tray2,
Rear Door
and remove paper
<IOT Remain Zone Regi + MSI + T1 + T2 Jam>
Cause:
When Dynamic Jam (cause) was detected:
• 077-106 Exit On Jam
When Static Jam (collateral) was detected:
•Regi Sensor On
FIP 1. 259
050-134
Paper Jam
Open Bypass Tray,
Tray1, and
remove paper
Press OK to start
<IOT Zone MSI+T1 Jam>
Cause:
When Dynamic Jam (cause) was detected:
• 071-100 IOT Tray1 Misfeed Jam
• 075-100 MSI Misfeed Jam
FIP 1. 260
050-135
Paper Jam
Pull Out Tray4
Clear Jam. Or
Clear Jam From
Back of Tray.
Press OK to start
<IOT Zone T2 + T3 + T4 + TR2 + TR3 Jam>
Cause:
When Dynamic Jam (cause) was detected:
• 073-101 IOT Path3 SNS On Jam
When Static Jam (collateral) was detected:
• Tray2 Path Sensor On, Tray3 Path Sensor On,
and Tray4 Path Sensor On
FIP 1. 261
050-136
Paper Jam
Pull Out Tray3,4,
Clear Jam. Or
Clear Jam From
Back of Tray3.
Press OK to start
<IOT Zone T3 + T4 + TR3 Jam>
Cause:
When Dynamic Jam (cause) was detected:
• 072-101 IOT Path2 SNS On Jam
When Static Jam (collateral) was detected:
•Tray3 Path Sensor On
FIP 1. 262
050-137
Paper Jam
Pull Out Tray3
Clear Jam. Or
Clear Jam From
Back of Tray.
Press OK to start
<IOT Zone T2 + T3 + TR2 + TR3 Jam>
Cause:
When Dynamic Jam (cause) was detected:
• 072-102 IOT Option Regi On Jam
When Static Jam (collateral) was detected:
• Tray2 Path Sensor On and Tray3 Path Sensor
On
FIP 1. 263
Status
Code
(3610)
LCD Message Name/Description of Error FIP