8 Frequency Scan Measurement
Marker To
Marker To
Displays the menu keys that enable you to append new elements into the existing signal list.
Key Path
Front-panel key
Notes Front panel only.
Initial S/W Revision A.07.00
Marker à List
Appends the frequency where the selected marker is in the signal list. The location of the newly added
signal depends on the auto sort setting. If the trace detector matches the signal list detector, the
corresponding amplitude and limit delta values will be updated. Otherwise, the values will be shown as “--
- to indicate an undefined value.
Key Path
Marker To
Remote Command
:CALCulate:FSCan:MARKer[1]|2|...|12[:SET]:SLISt
Example
CALC:FSC:MARK2:SLIS
Notes If there is no free space in the signal list, the following prompt message will ask you whether to
continue: WARNING! There is not enough free space in Signal List. Would you like to clear the Signal
list before adding signals? Press ENTER to continue or ESC to Cancel.
Couplings If no marker is ON when this operation is performed, the default marker will be turned on. The newly
added signal will become the selected signal in the list.
Initial S/W Revision A.07.00
Meas at Mkr Result à List
Appends the current measure at marker results into the signal list, which include the frequency, measure
at marker amplitude values and delta to limit values. For either case of detector or delta for limit lines is set
to off, the values will be shown as “---“ in the signal list to indicate the value is undefined.
If no valid measure at marker or final measurement is performed, an error is generated and a Measure at
Marker à List cannot be performed.
Key Path
Marker To
Remote Command
:CALCulate:FSCan:MAMarker[:SET]:SLISt
Example CALC:FSC:MAM:SLIS
Notes If you perform a final measurement before selecting Measure at Marker à List, the last final
measurement signal will be added to the list.
If there is no free space in the signal list, the following prompt message will ask you whether to
continue: WARNING! There is not enough free space in Signal List. Would you like to clear the Signal
list before adding signals? Press ENTER to continue or ESC to Cancel.
Couplings
The newly added signal will become the selected signal in the list.
Initial S/W Revision A.07.00
424 EMI Receiver Mode Reference

Table of Contents

Other manuals for Keysight PXA X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight PXA X Series and is the answer not in the manual?

Keysight PXA X Series Specifications

General IconGeneral
BrandKeysight
ModelPXA X Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals