The digital inputs must be congured such that they detect the frequency input signal
(0x2630:002 (P410.02)).
0x2630:002
a)
Input funcon 0x2630:002 (P410.02) = "Pulse train [2]"
(DI4 = input for pulse train, DI3 = normal digital input)
This selecon congures the digital inputs to detect the frequency signal, whereby DI4 is
congured to detect the frequency input signal (pulse train).
Controller
PTO1
PTO2
COM
Inverter
DI4
DI3
GND
X3
VDC
Pulse 4Pulse 1 Pulse 2 Pulse 3
Duty cycle (30 ... 70 %)
15 ... 24
0
t
b)
Input funcon 0x2630:002 (P410.02) = "Pulse train/direcon [3]"
(DI4 = input for pulse train, DI3 = input for specicaon of direcon)
This selecon congures the digital inputs to detect the frequency and direconal signals,
whereby the digital input DI4 is congured to detect the frequency input signal (pulse
train) and DI3 is congured to detect the direconal signal.
Controller
PTO1
PTO2
COM
Inverter
DI4
DI3
GND
X3
VDC
Pulse 4Pulse 1 Pulse 2 Pulse 3
Duty cycle (30 ... 70 %)
15 ... 24
0
t
LOW = FWD (CW)
HIGH = REV (CCW)
VDC
15 ... 24
0
t
Scaling
The scaling of the frequency signal in relaon to the setpoint range takes place in two steps
can be congured as follows:
Idenfy the minimum and maximum frequency of the frequency signal (pulse train).
Set the minimum frequency value (Hz). 0x2640:001 (P415.01)
When DI3 is used to control the pulse train 0x2630:002 (P410.02)= [3], this
value must be congured to the corresponding NEGATIVE pulse frequency
value.
Set the maximum frequency value (Hz). 0x2640:002 (P415.02)
Area
Congure the range for the setpoint, which corresponds to the minimum and maximum fre-
quency of the frequency signal (pulse train).
Frequency setpoint:
Set minimum desired motor frequency (Hz). 0x2640:003 (P415.03)
Set maximum desired motor frequency (Hz). 0x2640:004 (P415.04)
Process control:
Set minimum desired PID setpoint (PID controller). 0x2640:005 (P415.05)
Set maximum desired PID setpoint (PID controller). 0x2640:006 (P415.06)
I/O extensions and control connecons
Congure digital inputs
Congure digital inputs DI3/DI4 for detecng a pulse train