EasyManua.ls Logo

NEC Univerge SV8100 - Virtual Loop Back Port Setting

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 10.1 UNIVERGE SV8100
2 - 64 Program 10 : System Configuration Setup
Description
Use Program 10-42: Virtual Loop Back Port Setting to set the data for the Virtual
Loop Back Port.
Conditions
None
Feature Cross Reference
None
Program 10 : System Configuration Setup
10-42 : Virtual Loop Back Port Setting
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
Number of Loop Back Ports
0~30 (0 = No setting)
0
02
Logical Trunk Port Number
0~168
0
03
Logical Station Port Number
0~480
0
04
Layer 3 Timer Type
1~5
1
05
Calling Party Number
0 = No
1 = Yes
1
06
S-point DDI digits
0 - 4
0
07
Call Busy Mode for S-point
0 = Alerting Message
1 = Disconnect Message
0

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals