Programming Manual 2 - 453
Program
34
Description
Use Program 34-01: E&M Tie Line Basic Setup to define the basic settings
for each E&M Tie line.
Program 34 : Tie Line Setup
34-01: E&M Tie Line Basic Setup
Level:
IN
Input Data
Trunk Port Number 001~200
Item
No.
Item Input Data Default Description
Related
PRG
01
DID/E&M
Start
Signaling
0=2
nd
Dial Tone
1=Wink
2 = Immediate
3 = Delay
0 (OT)
2 (AU)
Set the start signaling
mode for DID and Tie
trunks. DID and Tie
trunks can use either
immediate start or
wink start signaling.
22-02
02
Receive Dial
Type
for E&M Tie
Line
0=DP
1=DTMF
1 10-09
03
E&M Dial-In
Mode
0 = Specify
Extension
Number
(Intercom)
1=Use
Conversion
Table (NTT)
0
Determine if the
incoming Tie Line call
should be directed as
an intercom call or if it
should follow the DID
Translation Table in
Program 22-11.
22-11
04
E&M Line Dial
Tone
0 = Disable (No)
1 = Enable (Yes)
1
Enter 1 if the Tie Line
should send dial tone
to the calling system
after the call is set up.
Enter 0 if the Tie Line
should not send dial
tone.

Table of Contents