Issue 10.1 UNIVERGE SV8100
2 - 316 Program 21 : Outgoing Call Setup
Description
Use Program 21-05: Toll Restriction Class to set the system Toll Restriction classes
(1~15).
Program 21 : Outgoing Call Setup
21-05 : Toll Restriction Class
Level:
IN
Input Data
Toll Restriction Class Number 1~15
Item
No.
Item Input Data Default Description
Related
PRG
01
International Call
Restriction Table
0 =Unassigned
(No)
1 = Assigned
(Yes)
1, 6~15 = 0
2~5 = 1
This option assigns/
unassigns the International
Call Restrict Table for the
Toll Restriction Class you
are programming. Enter
International Call Restrict
Table data in Program 21-
06-01.
21-06-01
02
International Call
Permit Code Table
0 =Unassigned
(No)
1 = Assigned
(Yes)
1, 3~15 = 0
2 = 1
This option assigns/
unassigns the International
Call Permit Table for the Toll
Restriction Class you are
programming. Enter
International Call Permit
Table data in Program 21-
06-02.
21-06-02
04
Maximum Number
of Digits Table
Assignment
1~4 = Table
0 = Disable
(None)
1, 2, 6~15 =
0
3 = 1
4 = 2
5 = 3
Select the table (defined in
21-06-03) to be used to
determine the maximum
number of digits allowed for
outgoing calls.
21-06-03
05
Common Permit
Code Table
0 =Unassigned
(No)
1 = Assigned
(Yes)
1, 8~15 = 0
2~7 = 1
It chooses whether the table
set up by 21-06-04 is
referred to, or not referred
to.
21-06-04
06
Common
Restriction Table
0 =Unassigned
(No)
1 = Assigned
(Yes)
1, 6~15 = 0
2~5 = 1
It chooses whether the table
set up by 21-06-05 is
referred to, or not referred
to.
21-06-05