Description
Use Program 20-31: Timer Class Timer Assignment to assign values to the timers
on a class of service basis.
Program 20 : System Option Setup
20-31 : Timer Class Timer Assignment
Level:
IN
Input Data
Timer Class Number 0~15
Item
No.
Item
Input Data
(sec)
Default
(sec)
Related
PRG
01
Trunk Queuing Callback Duration Time
Trunk Queuing Callback rings an extension
for this amount of time
0~64800
15 20-01-08
02
Callback / Trunk Queuing Cancel Time
The system cancels an extension Callback
or Trunk Queueing request after this amount
of time.
0~64800
64800 20-01-09
03
Virtual Extension Delay Interval
Virtual Extensions set for Delayed Ringing
(refer to 15-11 : Virtual Extension Delayed
Ring Assignment) ring the extension after
this time.
0~64800
10 20-04-03
04
Intercom Interdigits Time (Intercom I/D
Timer)
When placing Intercom calls, extension
users must dial each digit in this time.
0~64800
10 21-01-02
05
Trunk Interdigits Time (Trunk I/D Timer)
The system waits for this time to expire
before placing the call in a talk state (Call
Timer starts after time expires, Voice Over
and Barge-In are not allowed until after time
expires).
0~64800
10 21-01-03
06
Hotline Time Start Time (Hotline Start)
A Ringdown extension automatically calls
the programmed destination after this time.
0~64800
5 (OT)
0 (AU)
21-01-09