EasyManua.ls Logo

NEC Univerge SV8100 - Program 25: VRS;DISA Setup; VRS;DISA Line Basic Data Setup

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming Manual 2 - 387
Program
25
Description
Use Program 25-01 : VRS/DISA Line Basic Data Setup to define the basic
setting of each VRS/DISA line.
Conditions
None
Feature Cross Reference
Direct Inward System Access (DISA)
Program 25 : VRS/DISA Setup
25-01 : VRS/DISA Line Basic Data Setup
Level:
IN
Input Data
Trunk Port Number 001~200
Item
No.
Item Input Data Default
Related
Program
01
VRS/DISA Dial-In Mode
0 = Extension Number
Service Code
Specify (Intercom)
1 = Use Dial
Conversion Table
0 22-11
02
DISA User ID
0=Off
1=On
1 (OT)
0 (AU)
25-08
03
VRS/DISA Transfer Alarm
0=Normal (Off)
1=Alarm (On)
0