Issue 10.1 UNIVERGE SV8100
2 - 770 Program 84 : Hardware Setup for VoIP
Description
Use Program 84-03: IP Phone Information Basic Setup to define the details of
Dterm IP.
Program 84 : Hardware Setup for VoIP
84-03 : IP Phone Information Basic Setup
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
NGT Signal Receive Port Number
Define the receiving port for IP control protocol
0-65535
3458
02
DRS Port Number
Define the port number for the Device Registration
Server.
0-65535
3456
06
Area Number
0 = Japan
1=USA
2 = Australia
3=EU
4=Asia
5 = Other Country
6 = Germany
7=Italy
8 = Netherlands
9 = Austria
10 = Belgium
11 = Spain
12 = Sweden
13 = UK
14 = Denmark
15 = Greece
16 = Switzerland
17 = RSA
18 = New Zealand
3 (OT)
2 (AU)
07
Type of Service Mode
Set the type of service (ToS) mode.
1: Invalid
2: IP Precedence
3: Diffserve
1