Issue 10.1 UNIVERGE SV8100
2 - 744 Program 82 : Basic Hardware Setup for Extension
Description
Use Program 82-05: ISDN BRI & PRI Layer2 (S-Point) Initial Data Setup to set the
basic data for the Layer 2 of ISDN BRI/PRI S-Point.
Conditions
None
Feature Cross Reference
None
Program 82 : Basic Hardware Setup for Extension
82-05: ISDN BRI&PRI Layer2 (S-Point) Initial Data Setup
Level:
MF
Input Data
Item No. Item Input Data Default
01
Timer T200
1~255 (100~25500ms)
10(1sec)
02
Timer T201
1~255 (100~25500ms)
10(1sec)
03
Timer T202
1~255 (100~25500ms)
20 (2sec)
04
Timer T203
1~255 (100~25500ms)
100(10sec)
05
N200
1~255
3
06
N201
1~ 65535 (Byte)
260
07
N202
1~255
3