UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 369
Description
Use Program 22-17: Dial-In Conversion Table Area Setup for Time Pattern to
define Time Zone and Dial-In Conversion Table (Program 22-11) for Time Pattern.
Conditions
None
Feature Cross Reference
None
Program 22 : Incoming Call Setup
22-17: Dial-In Conversion Table Area Setup for Time Pattern
Level:
SA
Input Data
Conversion Table Number 01~500
Time Pattern No. 1~8
Item
No.
Item Input Data Default
01
Received Dial
Up to eight digits
No Setting
02
Start of Time
0000~2359 (Time)
0000
03
End of Time
0000~2359 (Time)
0000
04
Dial-In Conversion Table
Number
0~2000
0
05
Day of Week
0 = Off
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
8 = Saturday
9 = Holiday
1