UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 661
Description
Use Program 51-16: NetLink System Data Replication Mode Setting to set the
system data replication between the Primary and Secondary systems.
Program 51 : NetLink Service
51-16: NetLink System Data Replication Mode Setting
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
System Data Replication Mode
Sets the synchronous mode of the system data.
When set to 1 (Setting Time Mode), the systems
are synchronized at the time set in Item 02
below.
When set to 2 (Interval Mode), the systems are
synchronized at regular time intervals set in Item
03 below.
0 = Disable
1 = Setting Time Mode
2 = Interval Mode
0
02
System Data Replication Time Setting
Sets the time of day that both systems
synchronize database (when Item 01 is set to 1.)
0000~2359
0200
03
System Data Replication Interval Setting
Sets the time interval that both systems
synchronize database (when Item 01 is set to 2).
15~1440 (minutes)
30
(min.)
04
Replication Time Stamp
Show next replication time. (Read-Only)
Month: 0~12
–
Day: 0~31
–
Hour: 00~23
–
Minute: 00~59
–
05
System Data Replication Wait Time
This sets the wait time until replication starts
when NetLink is created.
1~86400 (seconds)
(86400sec, 1day)
180 sec
(3min)
06
System Data Replication Interval
This program sets an interval time to start
replication to the next node after replication to
one node is completed.
0~86400 (seconds)
(86400sec, 1day)
1 sec