Issue 10.1 UNIVERGE SV8100
2 - 38 Program 10 : System Configuration Setup
Description
Use Program 10-20 : LAN Setup for External Equipment to define the TCP port/
address/etc. for communicating to external equipment.
Program 10 : System Configuration Setup
10-20 : LAN Setup for External Equipment
Level:
IN
Input Data
Type of External Equipment
1=CTI Server
2=ACD MIS
3=Not Used
4 = Networking System (OT)
5 = SMDR Output
6 = DIM Output
7=Reserved
8=Reserved
9 = 1st Party CTI
10 = ACD Agent Control
11 = O&M Server
12 = Traffic Report Output
13 = Room Data Output for Hotel
Service
14 = IP DECT Directory Access
Item
No.
Item Input Data Default
01
TCP Port
0~65535 External Device 1 (CTI Server) = 0
External Device 2 (ACD MIS) = 0
External Device 4 (Networking System)
= 30000 (OT)
External Device 5 (SMDR Output) = 0
External Device 6 (DIM Output) = 0
External Device 11 (O&M Server) = 8010
External Device 12 (Traffic Report Output) = 0
External Device 13 (Room Data Output for
Hotel Service) = 0
External Device 14 (IP DECT Directory
Access) = 0
03
Keep Alive Time
1~255 (sec) 30

Table of Contents