UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 343
Description
Use Program 22-02: Incoming Call Trunk Setup to assign the incoming trunk type
for each trunk. There is one item for each Night Service Mode.
Conditions
When connecting to T1 trunks, after changing Program 22-02-01 to match the
Telco connected T1 service type, the T1 cable or the T1 blade must be unplugged
and then reconnected for the T1 blade to sync.
When the trunk type is set to 3 (DID), the DID Transfer to Destination in 22-11-04
for each DID feature is not supported. This feature is supported only for DID
trunks when assigned as VRS.
When the trunk type is set to 3 (DID), the DID Intercept Destination feature for
each DID is not supported. This feature is supported only for DID trunks assigned
as VRS.
Program 22 : Incoming Call Setup
22-02: Incoming Call Trunk Setup
Level:
IN
Input Data
Trunk Port Number 001~200
Day/Night Mode 1~8
Item
No.
Item Input Data Default Description
Related
Program
01
Incoming
Type
0 = Normal
1 = VRS (second
dial tone if no
VRS installed)
2=DISA
3=DID
4=DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode
Switching
0
Use this option to set the
feature type for the trunk
you are programming.
14-04