EasyManua.ls Logo

NEC Univerge SV8100 - IP Telephone Terminal Basic Data Setup

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 10.1 UNIVERGE SV8100
2 - 188 Program 15 : Extension, Basic Setup
Description
Use Program 15-05: IP Telephone Terminal Basic Data Setup to set up the basic
settings for an IP telephone.
Program 15 : Extension, Basic Setup
15-05 : IP Telephone Terminal Basic Data Setup
Level:
IN
Input Data
Extension Number Maximum eight digits
Item
No.
Item Input Data Default Description
Related
Program
01
Terminal Type
0= NGT
1= H.323
2= SIP
3 = MEGACO
4= SIP-MLT
-
Viewing Only –
No changes
permitted
02
IP Phone
Fixed Port
Assignment
MAC address
00-00-00-00-00-00 to
FF-FF-FF-FF-FF-FF
00-00-00-00-
00-00
MAC Address of
registered SIP
MLT phone is
stored and/or can
input the MAC
address of an SIP
MLT phone so
when it comes
online it is
provided with the
extension in
which the MAC
address matches.
15-05-01
03
Default URL
address
URL address - 192
Characters Max.
No setting
The default URL
address for Smart
Phone
15-05-01

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals