2 - 864 Program 90 : Maintenance Program
Description
(This program is available via telephone programming and Web Programming, but
not through PC Programming).
Use Program 90-06: Trunk Control for trunk maintenance. Busy Out lets you block a
blade from placing outgoing calls (just like placing the blade switch down). Once
busied out, none of the ports on the blade can be used for new calls. Existing calls,
however, are not torn down.
Conditions
None
Feature Cross Reference
None
Program 90 : Maintenance Program
90-06: Trunk Control
Level:
SA
Input Data
Menu Number
0 = Set Busy Out
1 = Reset Busy Out (idle)
Item
No.
Item Input Data Default
01
Trunk Control
Trunk Port Number: 001~200 1